🔌 Power Up Your Safety Game!
The Wattson 13A Fused RCD Spur Unit is a top-tier safety device designed for modern homes and offices. With a pre-loaded 13A fuse and passive operation, it ensures effortless protection against electrical faults while exceeding British safety standards. Its rapid trip speed and sleek design make it a must-have for any safety-conscious professional.
Q**G
Good price for a safety device.
This is an unbiased review. I did not get this free or at discount. I mention this for at least one reviewer believes this products reviews are fake.This is a great product, I had no problem replacing an existing fused spur with this, it fitted in the galvanised surface mount box with ease.This type of safety device is recommended for use with kitchen underfloor heating kits and for this reason I replaced my existing fused spur with this one.I selected this particular device because of the 3 push button switches which are very clear, colour coded, and easy to operate at near floor level under a kitchen worktop.The third button pops the fuse out and in doing so removes the supply which is indicated by a lamp. Someone suggested this is good to test the fuse with but personally I would use a hand held multimeter for this. This is a good feature as no tool (screwdriver) is required to replace any fuse that blows. Even an RCD will blow a fuse if overall circuit current is exceeded, the purpose of a RCD is to limit low currents passing through the operator in the event of a fault in the attached circuit.I'm pleased with this product, it does what it's designed for, and I'm very likely to buy more of this make in the future
S**6
No information provided.
I have not yet installed this so assume that electrically it is ok. However there are no instructions provided and some additional information would be useful, particularly on connecting the earth terminals. For example are these bridged internally and are the two securing screws also earthed or should separate provision be made? Furthermore the terminal identification and the engraved text is very difficult to read.
S**)
Nice unit, if it did what I needed.
Nice looking unit with easy terminals for wiring. Fuse ejection button is a really nice idea. Problem I faced was that the RCD in this unit did not trip locally. The test button resulted in tripping out the house RCD which defeated the purpose of installing a localised RCD spur in the garage. Regrettably returned.
G**E
Works great
Works great as expected, the LED is brighter than it needs to be (actually provides a lot of light at night)
P**.
VFM fitting.
Reasonable value for money. Terminals a bit fiddly and the brass is not good quality. My fitting had tight thread tolerances on the terminals and wás difficult to tighten satisfactorily without risk of damage to the screw slot because ot the soft brass
S**5
Four Stars
Decent quality although fuse carrier is very tricky to remove.
J**N
Did not work
Next time I'll go to B&Q
B**O
Four Stars
Did exactly what I wanted it for, very efficient.