🌟 Stay Cool, Stay Connected!
The SenvilleLETO Series Mini Split Air Conditioner Heat Pump is a powerful 18000 BTU unit that combines advanced inverter technology with Alexa compatibility, offering a versatile 4-in-1 solution for heating, cooling, dehumidifying, and fan functions. With a sleek design, whisper-quiet operation, and a robust 5-year warranty, it's the perfect choice for both residential and commercial spaces.
Energy Star | Not Compliant |
Warranty Type | Limited |
Capacity | 1.5 Tons |
Controller Type | Remote Control, App Control, Voice Control |
Wattage | 1645 |
Seasonal Energy Efficiency Ratio (SEER) | 19 |
Additional Features | Inverter Technology, Alexa Enabled |
Efficiency | High |
Control Method | Remote |
Power Source | Electric (Professional Installation) |
Voltage | 220 |
Inverter Type | Has Inverter |
Noise | 30 dB |
Is Product Cordless | No |
Installation Type | Split System |
Cooling Power | 18000 British Thermal Units |
Compressor Type | rotary_scroll |
Form Factor | Mini-Split |
Color | White |
Refrigerant | R-410A |
Item Weight | 78.3 Pounds |
Item Dimensions D x W x H | 40"D x 48"W x 40"H |
K**L
Excellent aftersales support.
There were a couple of issues that happened with my order. One was that the outdoor unit did not work. Long story short there was no refrigerant in it. I got in touch with customer service and after listening to me they promptly sent in another outdoor unit which arrived after several days. After that one was hooked up everything was working well. Cools and heats the room that it's installed in very well. I could control the unit with the remote but I could never get the Wi-fi to work. Apparently the Wi-fi dongle was missing. I reached out to customer service again and they sent a new Wi-fi dongle. After that got installed I was able to connect this with Wi-fi and then control it through my phone.So far so good. The unit is working very well. I guess sometimes you just get a lemon but the company made everything right. I would not hesitate to order another unit from them given the fact that they stand by their product.
J**G
Installed myself with no issues.
Cannot say enough about this unit. I installed it myself and had to vacuum the lines as they were not precharged but that comes with a cost savings. We have 2 of these and typically only use them in the room we are in at the time. My wife loves having the remote to control the temperature and turn the unit on and off as well as the fan speed. I originally bought this for the A?C unit to replace my central air but when my wife found out it had heat as well she started using that also over our furnace. We have to watch our money nowadays so to make a couple rooms comfortable and leave the others cool in the winter. Plus this has a high seer rating.
D**D
Great product-- Difficult DIY
This is a great, high-quality product that functions well. I thoroughly recommend the Senville for quality and performance.The install is a difficult level DIY and should only be attempted after proper research and with proper tools.Physically installing the units is easy. Wiring the units is not difficult but is time consuming, especially accounting for running a dedicated 20A electrical circuit.Line set installation is more involved. I chose to hang the inside unit before attaching the line set because of how I chose to run the refrigerant piping inside the room and then straight through the wall to the outside unit. I made my own wall pass-through sleeve from 3" pvc to give a little more working space. The included sleeve is very thin and flimsy. Line set flare nuts MUST be torqued to spec. I had one nut that failed and had to remove, replace with an included extra, and reflare the connection when I found the leak during the first pressure test. I shortened the refrigerant piping at the outside unit to fit with no looping of pipes. I used an eccentric flaring tool to remake the connection after shortening.Next step of pressure testing with nitrogen MUST NOT BE OMITTED. You will need a HVAC charging manifold, special fittings, a micron vacuum gauge, HVAC leak test soap, a compressed nitrogen tank and regulator, and a vacuum pump. A competent pro installer will do this--but many HVAC techs skip the pressure test step.I pressure tested and found the bad flare nut leak, repaired it, and pressure tested again to 300psi nitrogen. This forces most air and water out of the lines. I left the lines on pressure, applied leak test soap and left the set up for over 1 hour. There was absolutely no leakage according to the HVAC manifold gauge.After pressure testing, a vacuum test was performed using a micron vacuum gauge to make sure all nitrogen, air and water vapor was removed from the lines. You will need special fittings as mentioned, to insure that the lines remain isolated from the pump after evacuating. I vacuumed down to 220microns and let it sit for 30+ minutes. The gauge remained well below 300 microns. (the standard is to remain below 500 microns). This step double checks for leakage and confirms removal of all gasses and water before releasing the factory charge into the system. Next, isolate the gauge from the system using the special fittings, and release the refrigerant charge from the compressor into the system. After a final check for leaks after removing all gauges and fittings, the system was ready to power up and test run.Note: the flare nuts are crudely shaped on the outside (seem to be cast, rather than machined) so normal open ended wrenches do not fit them well. You will have to use adjustable wrenches to adjust them when installing. Using a torque wrench on those flare nuts is difficult because of the non-standard finish and sizing. A $175 adjustable wrench head HVAC torque wrench (made by Yellow Jacket) would really assist here, but I had a standard torque wrench with crow's foot wrench adapters. I made it work... but that's not an easy way to do it. I doubt many techs carry the special torque wrench and will just do the flare nuts by feel based on experience.The test run of the unit revealed no leaks, so I wrapped up the line set at the connection points and finished the install. I used a line set cover flashing to protect the lines where they emerged from the outside wall. Zip ties where needed to secure the wrapping tape. Big HVAC type zip ties screwed to the wall to mount the indoor line set in permanent fashion. double checked the drain line was working properly without restriction by pouring water in the top of the inside unit and verifying full drainage. I left the primary drain line joint uncovered inside so I could have access if there was ever a blockage.The unit heats wonderfully, cooling is great, too, but I will have to confirm how that works on a really hot day this summer. You will have to run the cooling check on manual cool override if temperature is below 62º outside (it was cool here on the test day). The air output on cooling feels ice-cold.Spend the time and money to install it correctly and the Senville will serve you well, I think. If you are not comfortable doing it DIY, then hire a good installer.You will not have factory warranty without a professional installer according to Senville. I chose DIY anyway after researching the process and finding than some installers skip the pressure test. (Senville in fact does not insist on a pressure test in the install manual.)22 months in, I could not be more pleased. Keeps my garage/workshop comfortable year round (outside temps ranging from 7° to 97°) and has very little impact on my power bill. Just keep the filters and fins clean for best efficiency. So far, I have not needed to clean the blower wheel. No problems with the condensate drain at all.
M**Y
Quality
I was very skeptical when I saw this product at this price. It came very quickly. It is a complete unit. You will need some special equipment, ( gages, vacuum, etc. ), but your installer will have all that. The installation is very straightforward and simple. The unit works incredibly well with very little noise. I’m looking forward to see what kind of savings I’ll see with this over the old hvac unit I had for my shop. My shop is 24 x 24 with 8’ walls, approximately 540sf and calculations state the need for at least 12k btu. Went with the 18k btu to be sure. Great! That’s how I’d sum this whole experience up. Thank you for an outstanding product.
Trustpilot
4 days ago
2 weeks ago